Sorensen SGI800-13

DC Power Supply, 800V, 13A, 10kW

Manufacturer:
Model: Sorensen SGI800-13
Description: DC Power Supply, 800V, 13A, 10kW
Data Sheet PDF: Sorensen SGI800-13

SORENSEN SGI800-12.5 DC Power Supply, 800V, 12.5A, 10kW (call for availability)The Sorensen SGI800-12.5 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.The Sorensen SGI800-12.5 DC Power Supply (SGI = Sorensen General Purpose Intelligent) combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the Sorensen SGI800-12.5 DC Power Supply ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the Sorensen SGI800-12.5 DC Power Supply. Features and Specifications of the Sorensen  SGA800-12.5 DC Power Supply include:

  • High Power Density: Up to 15 kW in a 3U chassis
  • Wide Voltage Range: 0-10V up to 0-800V, in increments of 5 kW from 5 to 30 kW
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise:  Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection 
  • Sequencing: Program custom waveforms
  • Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution:  Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server 
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only
  • Common:

  • Remote Sense:  Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply).
  • Parallel Operation:  Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
  • Series Operation:  Up to 2 units
  • Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 
      • 208/220 VAC (operating range 187 – 242 VAC)
      • 380/400 VAC (operating range 342 – 440 VAC)
      • 440/480 VAC (operating range 396 – 528 VAC)
  • Frequency:  47 – 63Hz , 400Hz
  • Power Factor: 
      • >0.9 typical for 208/220 VAC input (10V – 800V)
      • >0.78 typical for 380/400 VAC input (40V – 800V)
      • >0.9 typical for 380/480 VAC input (10V – 30V)
      • >0.7 typical for 440/480 VAC input (40V – 800V)
      • >0.9 typical for 440/480 VAC input (10V – 30V)
  • Protection:  ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
    • 208/220 VAC (operating range 187 – 242 VAC)
    • 380/400 VAC (operating range 342 – 440 VAC)
    • 440/480 VAC (operating range 396 – 528 VAC)
  • 208/220 VAC (operating range 187 – 242 VAC)
  • 380/400 VAC (operating range 342 – 440 VAC)
  • 440/480 VAC (operating range 396 – 528 VAC)
    • >0.9 typical for 208/220 VAC input (10V – 800V)
    • >0.78 typical for 380/400 VAC input (40V – 800V)
    • >0.9 typical for 380/480 VAC input (10V – 30V)
    • >0.7 typical for 440/480 VAC input (40V – 800V)
    • >0.9 typical for 440/480 VAC input (10V – 30V)
  • >0.9 typical for 208/220 VAC input (10V – 800V)
  • >0.78 typical for 380/400 VAC input (40V – 800V)
  • >0.9 typical for 380/480 VAC input (10V – 30V)
  • >0.7 typical for 440/480 VAC input (40V – 800V)
  • >0.9 typical for 440/480 VAC input (10V – 30V)
  • Output:

  • Voltage and Cur Range: 800V, 12.5A, 10kW
  • Ripple & Noise:
      • rms(20Hz-300kHz): 80mV
      • p-p: 500mV
    • rms(20Hz-300kHz): 80mV
    • p-p: 500mV
  • rms(20Hz-300kHz): 80mV
  • p-p: 500mV
  • Programming & Read-Back Specifications:

  • Front Panel Display:
    • Programming:
      • Accuracy: 
        •  (40-800V) +/- 0.1% of voltage at full scale
        • (40-800V) +/- 0.4% of cur at full scale
      • Resolution: 4.0 digits
    • Read-Back Monitoring:
      • Accuracy: 
        • Voltage: +/- 0.1% of full scale
        • Cur: +/- 0.4% of full scale
      • Resolution: 4.0 digits
    • Knob control & Display read-back
  • Remote Analog Interface: 
    • Programming:
      • Accuracy:
        • Voltage: +/-0.25% of full scale
        • Cur: (40-800V) 0.8% of full scale 
    • Read-Back Monitoring:
      • Accuracy: (40-800V) +/-1.0% of full scale
    • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Remote Digital Interface:
    • Programming:
      • Accuracy:
        • Voltage:  +/- 0.1% of full scale
        • Cur: +/- 0.4% of full scale
      • Resolution: +/-0.002% of full scale
    • Read-Back Monitoring:
      • Accuracy:
        • Voltage:  +/- 0.15% of full scale
        • Cur:  +/- 0.4% of full scale
      • Resolution:  +/-0.002% of full scale
    • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • OVP:
    • Programming:
      • Accuracy: +/- 1% of full scale
      • Resolution: +/-0.002% of full scale
    • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • User I/O:
    • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Programming:
    • Accuracy: 
      •  (40-800V) +/- 0.1% of voltage at full scale
      • (40-800V) +/- 0.4% of cur at full scale
    • Resolution: 4.0 digits
  • Read-Back Monitoring:
    • Accuracy: 
      • Voltage: +/- 0.1% of full scale
      • Cur: +/- 0.4% of full scale
    • Resolution: 4.0 digits
  • Knob control & Display read-back
  • Accuracy: 
    •  (40-800V) +/- 0.1% of voltage at full scale
    • (40-800V) +/- 0.4% of cur at full scale
  • Resolution: 4.0 digits
  •  (40-800V) +/- 0.1% of voltage at full scale
  • (40-800V) +/- 0.4% of cur at full scale
  • Accuracy: 
    • Voltage: +/- 0.1% of full scale
    • Cur: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Voltage: +/- 0.1% of full scale
  • Cur: +/- 0.4% of full scale
  • Programming:
    • Accuracy:
      • Voltage: +/-0.25% of full scale
      • Cur: (40-800V) 0.8% of full scale 
  • Read-Back Monitoring:
    • Accuracy: (40-800V) +/-1.0% of full scale
  • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Accuracy:
    • Voltage: +/-0.25% of full scale
    • Cur: (40-800V) 0.8% of full scale 
  • Voltage: +/-0.25% of full scale
  • Cur: (40-800V) 0.8% of full scale 
  • Accuracy: (40-800V) +/-1.0% of full scale
  • Programming:
    • Accuracy:
      • Voltage:  +/- 0.1% of full scale
      • Cur: +/- 0.4% of full scale
    • Resolution: +/-0.002% of full scale
  • Read-Back Monitoring:
    • Accuracy:
      • Voltage:  +/- 0.15% of full scale
      • Cur:  +/- 0.4% of full scale
    • Resolution:  +/-0.002% of full scale
  • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • Accuracy:
    • Voltage:  +/- 0.1% of full scale
    • Cur: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • Voltage:  +/- 0.1% of full scale
  • Cur: +/- 0.4% of full scale
  • Accuracy:
    • Voltage:  +/- 0.15% of full scale
    • Cur:  +/- 0.4% of full scale
  • Resolution:  +/-0.002% of full scale
  • Voltage:  +/- 0.15% of full scale
  • Cur:  +/- 0.4% of full scale
  • Programming:
    • Accuracy: +/- 1% of full scale
    • Resolution: +/-0.002% of full scale
  • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •      Product Overview Sorensen SGI800-13 (call for availability) The Sorensen SGI800-13  is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI800-13 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI800-13 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI800-13.Features of the Sorensen SGI800-13 include:

  • High Power Density: 10kW in a 3U chassis
  • Wide Voltage Range: 0-800V and 0-13 Amps
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • Sequencing: Program custom waveforms
  • Easy-to-read Fluorescent Display: Supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only 
  • Specifications of the Sorensen SGI800-13 include:Common:

  • Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
  • Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
  • Series Operation: Up to 2 units (see Output Float Voltage)
  • Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 – 242 VAC); 380/400 VAC (operating range 342 – 440 VAC); and 440/480 VAC (operating range 396 – 528 VAC)
  • Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
  • Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and  >0.69 typical at 440/480 VAC input
  • Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
  • Environmental:

  • Operating Temperature: 0 to 50º C
  • Storage Temperature: -25º C to 65º C
  • Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
  • Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
  • Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
  • Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
  • Front Panel Dust Filter: 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature. 3U unit only.
  • Physical:

  • Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
  • Weight: 3U < 80 lbs. (36 kg) 6U
  • Output:

  • Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
  • Ripple (Cur Mode): <+/- 0.04% of full scale rms cur
  • DC Voltage Slew Rate: 45A / ms typical – resistive load
  • Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale
  • Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale
  • Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
  • Efficiency: 87% typical at nominal line and max load
  • Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
  • Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point
  • Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur.
  • Programming Specifications of the Sorensen SGI800-13 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
  • Cur Accuracy: 0.8% of full scale
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • OVP:

  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Read-Back / Monitoring Specifications of the Sorensen SGI800-13 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Accuracy: +/-1.0% of full scale (0 – 10V)
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •     

    Sorensen SGI800-13 Product Overview