Keysight (Agilent) E4360A

Modular Solar Array Simulator Mainframe, 1200W

Manufacturer:
Model: Keysight (Agilent) E4360A
Description: Modular Solar Array Simulator Mainframe, 1200W
Data Sheet PDF: Keysight (Agilent) E4360A

Agilent / HP E4360A Simulator Mainframe (call for availability)The Agilent / HP E4360A Modular Solar Array Simulator is a 2U high, 2-slot mainframe. Features and Specifications of the Agilent / HP E4360A Modular Solar Array Simulator Mainframe include:

  • Accurate simulation of any type of solar arraySmall size: up to 2 outputs in 2U of rack space
  • High output power – up to 600 W per output
  • Fast I-V curve change and fast recovery switching time
  • Easy to simulate environmental conditions
  • LAN, USB, and GPIB interfaces standard
  • Fully compliant to LXI Class C specifications
  • Custom turn-key system or individual instruments available
  • Accepts up to 2 E4360 series modules (modules are ordered separately)
  • Offers LAN, USB, and GPIB interfaces standard
  • Maximum Total Output Power (=Sum of Total Module Output Power)
    • 1200 W when operating from 200 – 240 VAC input
    • 600 W when operating from 100 – 120 VAC input
  • Protection Response Characteristics
    • INH input:  5 µs from receipt of inhibit to start of shutdown
    • Fault on coupled outputs:  < 10 µs from receipt of fault to start of shutdown
  • AC Mains
    • Nominal input ratings:  100/120/220/240 VAC; 50/60/400 Hz
    • Input range:  86 VAC – 264 VAC
    • Power consumption:  2000 VA (mainframe has power factor correction)
    • AC line spike ratings:  1 kV typical
    • Maximum Input Power:  2000 VA, 2000 W
    • Fuse:  15 A/250 VAC bib-time delay (Agilent p/n 2110-0054)
    • 100/120 VAC Note:  AC mains circuits rated at nominal 100-120 VAC cannot supply enough cur to power the E4360A mainframe when two output modules are installed. In this case, internal circuits will limit the output cur of the modules to one half of their rating. For a single installed module, full output cur will be available at nominal 100-120 VAC
  • Savable States
    • Memory locations:  2 (0 and 1)
    • Pre-stored state:  0
  • Command Processing Time:   =1 ms from receipt of command to start of output change
  • Protection Response Characteristics
    • INH input:  5 µs from receipt of inhibit to start of shutdown
    • Fault on coupled outputs: 
  • Interface Capabilities
    • GPIB:  SCPI – 1993, IEEE 488.2 compliant interface
    • LXI Compliance:  Class C
    • USB 2.0:  Requires Agilent IO Library version M.01.01 and up, or 14.0 and up
    • 10/100 LAN:  Requires Agilent IO Library version L.01.01 and up, or 14.0 and up
    • Built-in Web server:  Requires Internet Explorer 5+ or Netscape 6.2+
  • Environmental Conditions
    • Operating environment:  Indoor use, installation category II (for AC input), pollution degree 2
    • Temperature range:  0°C to 55°C (cur is derated 1% per °C above 40°C ambient temperature)
    • Relative humidity:  Up to 95%
    • Altitude:  Up to 2000 meters
    • Storage temperature:  -30°C to 70°C
    • LED statement:  Any LEDs used in this product are Class 1 LEDs as per IEC 825-1
  • 1200 W when operating from 200 – 240 VAC input
  • 600 W when operating from 100 – 120 VAC input
  • INH input:  5 µs from receipt of inhibit to start of shutdown
  • Fault on coupled outputs:  < 10 µs from receipt of fault to start of shutdown
  • Nominal input ratings:  100/120/220/240 VAC; 50/60/400 Hz
  • Input range:  86 VAC – 264 VAC
  • Power consumption:  2000 VA (mainframe has power factor correction)
  • AC line spike ratings:  1 kV typical
  • Maximum Input Power:  2000 VA, 2000 W
  • Fuse:  15 A/250 VAC bib-time delay (Agilent p/n 2110-0054)
  • 100/120 VAC Note:  AC mains circuits rated at nominal 100-120 VAC cannot supply enough cur to power the E4360A mainframe when two output modules are installed. In this case, internal circuits will limit the output cur of the modules to one half of their rating. For a single installed module, full output cur will be available at nominal 100-120 VAC
  • Memory locations:  2 (0 and 1)
  • Pre-stored state:  0
  • INH input:  5 µs from receipt of inhibit to start of shutdown
  • Fault on coupled outputs: 
  • GPIB:  SCPI – 1993, IEEE 488.2 compliant interface
  • LXI Compliance:  Class C
  • USB 2.0:  Requires Agilent IO Library version M.01.01 and up, or 14.0 and up
  • 10/100 LAN:  Requires Agilent IO Library version L.01.01 and up, or 14.0 and up
  • Built-in Web server:  Requires Internet Explorer 5+ or Netscape 6.2+
  • Operating environment:  Indoor use, installation category II (for AC input), pollution degree 2
  • Temperature range:  0°C to 55°C (cur is derated 1% per °C above 40°C ambient temperature)
  • Relative humidity:  Up to 95%
  • Altitude:  Up to 2000 meters
  • Storage temperature:  -30°C to 70°C
  • LED statement:  Any LEDs used in this product are Class 1 LEDs as per IEC 825-1
  •     

    Keysight Agilent

    Keysight (Agilent) E4360A Product Overview