Rohde & Schwarz FSW67

Analizator sygnału i widma, 2 Hz – 67 GHz

Producent:
Model: Rohde & Schwarz FSW67
Opis: Analizator sygnału i widma, 2 Hz - 67 GHz
Arkusz danych PDF: Rohde & Schwarz FSW67

Rohde & Schwarz FSW67 SIGNAL AND SPECTRUM Analyser The high performance Rohde & Schwarz (R&S) FSW67 Signal and Spectrum Analyser is designed for convenience, accuracy and speed. Its unique touchscreen, straightforward, multiview result display, and optimized user guidance makes operation of the R&S FSW67 Analyser efficient and convenient. With its unmatched phase noise, unparalleled dynamic range for spurious measurements, and high sensitivity even at low frequences, the R&S FSW67 guarantees high accuracy. Efficient measurement rates, rapid sweep times, quick switchover between instrument setups, makes operation fast and easy.Features and Specifications of the Rohde & Schwarz FSW67 Signal and Spectrum Analyser include:Features of the R&S FSW67 Analyser:

  • Excellent dynamic range for spurious measurements because of low DANL
  • Harmonic measurements made easy and accurate due to integrated highpass filters:
    • High sensitivity even at low frequencies
    • Unparalleled dynamic range up to 1 GHz with separate receive path
  • Up to 500 MHz analysis bandwidth
  • High spurious-free dynamic range of > 100 dBc
  • Large I/Q memory depth for seamless recording of long signal sequences
  • Efficient operation with optimized user guidance
  • MultiView: multiple results available at a glance
  • Ideal for measuring oscillators for radar and communications applications as well as for analyzing radar systems:
    • Fast identifcation and analysis of spurious emissions 
    • Measuring pulse parameters at the touch of a key
    • Detection of widespread frequency-hopping signals
    • Analyzing short pulse rise and fall times
  • Identifying interaction between signals
    • Multistandard radio Analyser (MSRA) 
    • Multistandard realtime Analyser (MSRT) 
  • High measurement rates and fast sweep times with sweep rates of up to 1000 sweeps/s 
  • Fast switchover between instrument setups
  • Efficient measurement functions speed up operation
  • Integrated support of R&S®NRP-Zxx power sensors
  • High sensitivity even at low frequencies
  • Unparalleled dynamic range up to 1 GHz with separate receive path
  • Fast identifcation and analysis of spurious emissions 
  • Measuring pulse parameters at the touch of a key
  • Detection of widespread frequency-hopping signals
  • Analyzing short pulse rise and fall times
  • Multistandard radio Analyser (MSRA) 
  • Multistandard realtime Analyser (MSRT) 
  • Specifications of the Rohde & Schwarz FSW67 Signal and Spectrum Analyser:

  • Frequency:
    • Frequency range: 2 Hz to 67 GHz
    • Aging of frequency reference:  1 x 10-7/year
      • With R&S®FSW-B4:  3 x 10-8/year 
  • Bandwidths:
    • Resolution bandwidths:
      • Standard filter:  1 Hz to 10 MHz
        • With R&S®FSW-B8:  80 MHz
      • RRC filter:  
        • NADC:  18 kHz
        • TETRA:  24.3 kHz  
        • 3GPP:  3.84 MHz
      • Channel filter:  100 Hz to 5 MHz
      • Video filter:  1 Hz to 10 MHz
    • I/Q Demodulation bandwidth:  10 MHz
      • With R&S®FSW-B28:  28 MHz
      • With R&S®FSW-B40:  40 MHz
      • With R&S®FSW-B80:  80 MHz
      • With R&S®FSW-B160:  160 MHz
      • With R&S®FSW-B320:  320 MHz
      • With R&S®FSW-B500:  500 MHz
  • Displayed average noise level (DANL):
    • 2 GHz: -156 dBm (1 Hz) typical
    • With R&S®FSW-B13:  -159 dBm (1 Hz) typical
    • 8 GHz: -156 dBm (1 Hz) typical
    • 20 GHz: -150 dBm (1 Hz) typical
    • 40 GHz: -144 dBm (1 Hz) typical
    • DANL with preamplifier (with R&S®FSW-B24): 
      • 8 GHz -169 dBm (1 Hz) typical
      • 20 GHz -166 dBm (1 Hz) typical
      • 40 GHz -165 dBm (1 Hz) typical
    • DANL with noise cancellation, preamplifier off:  -169 dBm (1 Hz) typical
  • Intermodulation:
    • Third-order intercept (TOI):  
      • f < 1 GHz:  +30 dBm (typical)
      • f < 3 GHz:  +25 dBm (typical)
      • 8 GHz to 26 GHz:  +17 dBm (typical)
      • 13.6 GHz to 26 GHz:  +15 dBm (typical) 
  • WCDMA ACLR dynamic range:
    • With noise cancellation:  88 dB
  • Phase noise:
    • 10 kHz offset from carrier:  
      • 500 MHz carrier: -140 dBc (1 Hz) typical
      • 1 GHz carrier: -137 dBc (1 Hz) typical
      • 10 GHz carrier: -128 dBc (1 Hz) typical
  • Total measurement uncertainty: 8 GHz < .04 dB
  • Frequency range: 2 Hz to 67 GHz
  • Aging of frequency reference:  1 x 10-7/year
    • With R&S®FSW-B4:  3 x 10-8/year 
  • With R&S®FSW-B4:  3 x 10-8/year 
  • Resolution bandwidths:
    • Standard filter:  1 Hz to 10 MHz
      • With R&S®FSW-B8:  80 MHz
    • RRC filter:  
      • NADC:  18 kHz
      • TETRA:  24.3 kHz  
      • 3GPP:  3.84 MHz
    • Channel filter:  100 Hz to 5 MHz
    • Video filter:  1 Hz to 10 MHz
  • I/Q Demodulation bandwidth:  10 MHz
    • With R&S®FSW-B28:  28 MHz
    • With R&S®FSW-B40:  40 MHz
    • With R&S®FSW-B80:  80 MHz
    • With R&S®FSW-B160:  160 MHz
    • With R&S®FSW-B320:  320 MHz
    • With R&S®FSW-B500:  500 MHz
  • Standard filter:  1 Hz to 10 MHz
    • With R&S®FSW-B8:  80 MHz
  • With R&S®FSW-B8:  80 MHz
  • RRC filter:  
    • NADC:  18 kHz
    • TETRA:  24.3 kHz  
    • 3GPP:  3.84 MHz
  • NADC:  18 kHz
  • TETRA:  24.3 kHz  
  • 3GPP:  3.84 MHz
  • Channel filter:  100 Hz to 5 MHz
  • Video filter:  1 Hz to 10 MHz
  • With R&S®FSW-B28:  28 MHz
  • With R&S®FSW-B40:  40 MHz
  • With R&S®FSW-B80:  80 MHz
  • With R&S®FSW-B160:  160 MHz
  • With R&S®FSW-B320:  320 MHz
  • With R&S®FSW-B500:  500 MHz
  • 2 GHz: -156 dBm (1 Hz) typical
  • With R&S®FSW-B13:  -159 dBm (1 Hz) typical
  • 8 GHz: -156 dBm (1 Hz) typical
  • 20 GHz: -150 dBm (1 Hz) typical
  • 40 GHz: -144 dBm (1 Hz) typical
  • DANL with preamplifier (with R&S®FSW-B24): 
    • 8 GHz -169 dBm (1 Hz) typical
    • 20 GHz -166 dBm (1 Hz) typical
    • 40 GHz -165 dBm (1 Hz) typical
  • DANL with noise cancellation, preamplifier off:  -169 dBm (1 Hz) typical
  • 8 GHz -169 dBm (1 Hz) typical
  • 20 GHz -166 dBm (1 Hz) typical
  • 40 GHz -165 dBm (1 Hz) typical
  • Third-order intercept (TOI):  
    • f < 1 GHz:  +30 dBm (typical)
    • f < 3 GHz:  +25 dBm (typical)
    • 8 GHz to 26 GHz:  +17 dBm (typical)
    • 13.6 GHz to 26 GHz:  +15 dBm (typical) 
  • f < 1 GHz:  +30 dBm (typical)
  • f < 3 GHz:  +25 dBm (typical)
  • 8 GHz to 26 GHz:  +17 dBm (typical)
  • 13.6 GHz to 26 GHz:  +15 dBm (typical) 
  • With noise cancellation:  88 dB
  • 10 kHz offset from carrier:  
    • 500 MHz carrier: -140 dBc (1 Hz) typical
    • 1 GHz carrier: -137 dBc (1 Hz) typical
    • 10 GHz carrier: -128 dBc (1 Hz) typical
  • 500 MHz carrier: -140 dBc (1 Hz) typical
  • 1 GHz carrier: -137 dBc (1 Hz) typical
  • 10 GHz carrier: -128 dBc (1 Hz) typical
  •  Read our 5G blog post – “Getting The Call For 5G Network Testing” to learn why the Rohde & Schwarz FSW67 in terms of pure built-in analysis power, is one of the best signal and spectrum Analysers for 5G testing.     

    Rohde & Schwarz

    Rohde & Schwarz FSW67 Product Overview