Fluke 287

Multimetr rejestrujący True-rms Electronics z TrendCapture

Producent:
Model: Fluke 287
Opis: Multimetr rejestrujący True-rms Electronics z TrendCapture
Arkusz danych PDF: Fluke 287

The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.Features and Specifications of the Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture include:

  • Functionality:
  • TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data
    • zoom in up to 14 times
  • Selectable ac filter (Smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy
  • Adjustable recording and auto hold thresholds
    • specify a percentage change in the readings that begins a new event
  • Large 50,000 count, 1/4 VGA display with white backlight
    • Multiple sets of measurement information can be simultaneously displayed at the same time
  • Logging function with expanded memory for unattended monitoring of signals over time
    • Using on-board TrendCapture users can graphically review logged readings without needing a PC
    • Store up to 15,000 recorded events
    • Reading memory
    • Log to PC
    • Interval/event logging
    • Logging memmory:  upt ot 10,000 readings
    • Multiple logging sessions possible without download
  • New (i) button on board help screens for measurement functions
  • Saved measurements allow you to name and recall measurements made in the field
  • Multi-lingual interface
  • Isolated optical interface
  • True-rms AC voltage and cur for accurate measurements on complex signals or non linear loads Measure up to 10 A (20 A for 30 seconds)
  • Temperature function
  • Relative mode to remove test lead resistance from low ohms or capacitance measurements
  • Premium test leads and alligator clips included
  • Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
  • Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job
  • Continuity beeper
  • Battery/fuse access
  • Elapse time clock
  • Real time clock for automatic time stamping of saved readings
  • Time of day clock
  • Min-Max-avg
  • Specifications:
  • Function: DC Volts / AC Volts
    • Range and Resolution: 00 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
      • Basic Accuracy: 0.025 % 0.4 % (true-rms)
  • Function: DC Cur / AC Cur
    • Range and Resolution: 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
      • Basic Accuracy: 0.15 % 0.7 % (true-rms)
  • Function: Temperature (excluding probe)
    • Range and Resolution:  -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
      • Basic Accuracy: 1.0%
  • Function: Resistance
    • Range and Resolution: 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
      • Basic Accuracy: 0.05 %
  • Function:  Capacitance
    • Range and Resolution: 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
      • Basic Accuracy: 1.0%
  • Function: Frequency
    • Range and Resolution: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
      • Basic Accuracy: 0.005 %
  • dBV/dBm
  • DC mV Resolution:  1 μV
  • Megohm Range:  up to 500 M
  • Conductance:  50.00 nS
  • Capacitance Range:  100 mF
  • Basic DC Accuracy:  0.025 %
  • AC Bandwidth:  100 kHz
  • Peak capture to record transients:  250 μs
  • Duty Cycle:  0.01 % to 99.99 %
  • Pulse Width:  0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
  • zoom in up to 14 times
  • specify a percentage change in the readings that begins a new event
  • Multiple sets of measurement information can be simultaneously displayed at the same time
  • Using on-board TrendCapture users can graphically review logged readings without needing a PC
  • Store up to 15,000 recorded events
  • Reading memory
  • Log to PC
  • Interval/event logging
  • Logging memmory:  upt ot 10,000 readings
  • Multiple logging sessions possible without download
  • Range and Resolution: 00 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
    • Basic Accuracy: 0.025 % 0.4 % (true-rms)
  • Basic Accuracy: 0.025 % 0.4 % (true-rms)
  • Range and Resolution: 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
    • Basic Accuracy: 0.15 % 0.7 % (true-rms)
  • Basic Accuracy: 0.15 % 0.7 % (true-rms)
  • Range and Resolution:  -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
    • Basic Accuracy: 1.0%
  • Basic Accuracy: 1.0%
  • Range and Resolution: 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
    • Basic Accuracy: 0.05 %
  • Basic Accuracy: 0.05 %
  • Range and Resolution: 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
    • Basic Accuracy: 1.0%
  • Basic Accuracy: 1.0%
  • Range and Resolution: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
    • Basic Accuracy: 0.005 %
  • Basic Accuracy: 0.005 %
  •     

    Fluke