Tektronix P5200A

Sonda, 50 / 500X differenziale ad alta tensione 50MHz

Produttore:
Modello: Tektronix P5200A
Descrizione: Sonda, 50 / 500X differenziale ad alta tensione 50MHz
Scheda dati PDF: Tektronix P5200A

Tektronix P5200A HIGH-VOLTAGE DIFFEIAL PROBEThe Tektronix P5200A High-Voltage Active Diffeial Probe can be used with any Oscilloscope and enables users to safely make measurements of floating circuits with their Oscilloscope grounded. This probe converts floating signals to low-voltage ground-referenced signals that can be displayed safely and easily on any ground-referenced Oscilloscope. Features and Specifications of the Tektronix P5200A Probe include:

  • Features:
    • Overrange indicator
    • Safety certified
    • Switchable attenuation
    • Switchable bandwidth limit
    • Applications:
      • Floating measurements
      • Switching power supply design
      • Motor drive design
      • Electronic ballast design
      • CRT display design
      • Power converter design and service
      • Power device evaluation
  • Specifications:
    • Attenuation:  50X / 500X
    • Diffeial voltage:  
      • 500X:  ±1300 V
      • 50X:  ±130 V
    • Common mode voltage:  ±1300 V
    • Maximum input voltage-to-earth:  1000 V CAT II
    • Bandwidth:  50 MHz
    • Overrange indicator
    • Safety certified
    • Switchable attenuation
    • Diffeial input impedance:  10 MΩ, 2 pF
    • Input impedance between each input and ground:  5 MΩ, 4 pF
    • Typical CMRR:
      • DC:  >80 dB
      • 100 kHz:  >60 dB
      • 3.2 MHz:  >30 dB
      • 50 MHz:  >26 dB
    • Connectivity:  BNC interface 
    • Cable length:  1.8 m
  • Overrange indicator
  • Safety certified
  • Switchable attenuation
  • Switchable bandwidth limit
  • Applications:
    • Floating measurements
    • Switching power supply design
    • Motor drive design
    • Electronic ballast design
    • CRT display design
    • Power converter design and service
    • Power device evaluation
  • Floating measurements
  • Switching power supply design
  • Motor drive design
  • Electronic ballast design
  • CRT display design
  • Power converter design and service
  • Power device evaluation
  • Attenuation:  50X / 500X
  • Diffeial voltage:  
    • 500X:  ±1300 V
    • 50X:  ±130 V
  • Common mode voltage:  ±1300 V
  • Maximum input voltage-to-earth:  1000 V CAT II
  • Bandwidth:  50 MHz
  • Overrange indicator
  • Safety certified
  • Switchable attenuation
  • Diffeial input impedance:  10 MΩ, 2 pF
  • Input impedance between each input and ground:  5 MΩ, 4 pF
  • Typical CMRR:
    • DC:  >80 dB
    • 100 kHz:  >60 dB
    • 3.2 MHz:  >30 dB
    • 50 MHz:  >26 dB
  • Connectivity:  BNC interface 
  • Cable length:  1.8 m
  • 500X:  ±1300 V
  • 50X:  ±130 V
  • DC:  >80 dB
  • 100 kHz:  >60 dB
  • 3.2 MHz:  >30 dB
  • 50 MHz:  >26 dB
  •     

    Tektronix

    Tektronix P5200A Product Overview