SORENSEN SGI60-500 DC Power Supply The Sorensen SGI60-500 represents the next generation of high power programmable DC power supplies. The SG Series is designed for exceptional load transient response, low noise and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. At the heart of the SGI60-500 is a 5 kW power module. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. Combinations of these chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system cur.SGI: Advanced Intelligent Control (Sorensen General purpose Intelligent): The SGI combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI. Specifications for the SORENSEN SGI60-500 DC Power Supply Include: See Datasheet for full specifications Product Overview SORENSEN SGI60-83 POWER SUPPLY (call for availability) The Sorensen SGI60-83 is a general purpose power supply designed specifically for laboratory test and systems applications requiring variable DC sources with good ripple and regulation characteristics. Features and Specifications of the Sorensen SGI60-83 Power Supply include:
Constant cur / constant voltage
Automatic crossover
Variety of user interfaces available including:
- Manual front-panel control
- Standard non-isolated remote analog control
- Optional GPIB
- Isolated remote analog control
Manual front-panel control
Standard non-isolated remote analog control
Optional GPIB
Isolated remote analog control
Specifications:
Input power:
- Voltage (Standard): 208/220 VAC±10% (tested to 187-242 VAC)
- Voltage (Options):
- 380/400 VAC±10% (tested to 342-440 VAC)
- 440/480 VAC±10% (tested to 396-528 VAC)
- Frequeny: 47 to 63 Hz
- Phases:
- 3-phase, 3-wire plus ground
- Not phase rotation sensitive
- Neutral not used
Front panel meter accuracy:
- Voltage: ±0.1% of full-scale
- Cur: ±0.4% of full-scale
Load regulation (Specified at no load to full load, nominal AC input):
- Voltage: 0.02% of maximum output voltage
- Cur: 0.1% of maximum output cur
Line regulation (Specified ±10% nominal AC input, constant load):
- Voltage: 0.01% of maximum output voltage
- Cur: 0.05% of maximum output cur
Transient response: A 50% step load will recover to within 0.75% of original value within 1 ms
Down programming: With no load the output will program from 100 to 10% in less than 1.5 seconds
Stability: ±0.05% of set point over 8 hours at fixed line, load, and temperature using remote sense and after 30 minute warm-up
Remote Control/Monitor:
- On/Off control via contact closure
- 6-120 VDC or 12-240 VAC
- TTL or CMOS switch
- Output voltage and cur monitor
- OVP limit set
- summary fault status
Power factor:
- ›0.9 typical for 208/220VAC input
- ›0.78 typical for 380/400VAC input
- ›0.7 typical for 440/480VAC input
Efficiency: 87% typical at full load, nominal line
Analog remote programming:
- Accuracy:
- Constant voltage: ±0.25% of full scale output for 0-5V range (±0.5% 0-10V range)
- Constant cur: ±0.8% of full scale output
- Overvoltage protection (OVP): ±1% of full scale output
- Resistive:
- Constant voltage (0-100%): 0-5 kΩ
- Constant cur (0-100%): 0-5 kΩ
- Voltage:
- Constant voltage (0-100%): 0-5 VDC or 0-10 VDC
- Constant cur (0-100%): 0-5 VDC or 0-10 VDC
- Overvoltage protection (OVP) (5-110%): 0.25-5.5 VDC
Remote sensing:
- Terminals are provided to regulate output voltage at point of load
- Maximum line drop 5% of rated output voltage per line for 40-100V models
- Maximum line drop 2% of rated output voltage per line for >100V models
Voltage (Standard): 208/220 VAC±10% (tested to 187-242 VAC)
Voltage (Options):
- 380/400 VAC±10% (tested to 342-440 VAC)
- 440/480 VAC±10% (tested to 396-528 VAC)
Frequeny: 47 to 63 Hz
Phases:
- 3-phase, 3-wire plus ground
- Not phase rotation sensitive
- Neutral not used
380/400 VAC±10% (tested to 342-440 VAC)
440/480 VAC±10% (tested to 396-528 VAC)
3-phase, 3-wire plus ground
Not phase rotation sensitive
Neutral not used
Voltage: ±0.1% of full-scale
Cur: ±0.4% of full-scale
Voltage: 0.02% of maximum output voltage
Cur: 0.1% of maximum output cur
Voltage: 0.01% of maximum output voltage
Cur: 0.05% of maximum output cur
On/Off control via contact closure
6-120 VDC or 12-240 VAC
TTL or CMOS switch
Output voltage and cur monitor
OVP limit set
summary fault status
›0.9 typical for 208/220VAC input
›0.78 typical for 380/400VAC input
›0.7 typical for 440/480VAC input
Accuracy:
- Constant voltage: ±0.25% of full scale output for 0-5V range (±0.5% 0-10V range)
- Constant cur: ±0.8% of full scale output
- Overvoltage protection (OVP): ±1% of full scale output
Resistive:
- Constant voltage (0-100%): 0-5 kΩ
- Constant cur (0-100%): 0-5 kΩ
Voltage:
- Constant voltage (0-100%): 0-5 VDC or 0-10 VDC
- Constant cur (0-100%): 0-5 VDC or 0-10 VDC
- Overvoltage protection (OVP) (5-110%): 0.25-5.5 VDC
Constant voltage: ±0.25% of full scale output for 0-5V range (±0.5% 0-10V range)
Constant cur: ±0.8% of full scale output
Overvoltage protection (OVP): ±1% of full scale output
Constant voltage (0-100%): 0-5 kΩ
Constant cur (0-100%): 0-5 kΩ
Constant voltage (0-100%): 0-5 VDC or 0-10 VDC
Constant cur (0-100%): 0-5 VDC or 0-10 VDC
Overvoltage protection (OVP) (5-110%): 0.25-5.5 VDC
Terminals are provided to regulate output voltage at point of load
Maximum line drop 5% of rated output voltage per line for 40-100V models
Maximum line drop 2% of rated output voltage per line for >100V models