Teseq NSG 4070 Conducted RF Immunity Test SystemThe Teseq NSG 4070, successor of the NSG 2070, is a multifunctional EMC immunity test system. Its large frequency range from 9 kHz to 1 GHz and its modular set-up using internal or external amplifiers enable a large variety of applications including tests according to IEC 61000-4-6, various BCI applications as well as signal generator and power meter for test systems as per IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 and many other applications. The powerful and easy to use fi rmware makes the NSG4070 independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front panel.Features of the Teseq NSG4070 include:
Integrated signal generator 9 kHz to 1 GHz
3 power meter inputs 9 kHz to 1 GHz
Integrated power amplifier module for diffe applications
Multiple EUT monitoring options
5.7“ TFT color display
Internal, menu-based control software
Basic remote control software and report generator included
Specifications of the Teseq NSG4070 include:Generator:
RF
Frequency range: 9 kHz – 1 GHz
Resolution: 1 Hz
Reference frequency: 10 MHz Reference output
RF Level
Level range: -60 dBm to +10 dBm
Resolution: 0.1 dB
Settling time: 10 ms
Amplitude modulation
Modulation depth: 0 – 100%
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution: 1 Hz
Pulse modulation
Rise / fall time (10% / 90%): < 1 µs
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution: 1 Hz
Duty cycle: 10% to 90%
External modulation
Delay time: < 1 µs / 180°
Period: min. 20 µs
Pulse width: min. 10 µs
Frequency range: 9 kHz – 1 GHz
Resolution: 1 Hz
Reference frequency: 10 MHz Reference output
Level range: -60 dBm to +10 dBm
Resolution: 0.1 dB
Settling time: 10 ms
Modulation depth: 0 – 100%
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution: 1 Hz
Rise / fall time (10% / 90%): < 1 µs
Modulation frequency range: 1 Hz – 50 kHz
Frequency resolution: 1 Hz
Duty cycle: 10% to 90%
Delay time: < 1 µs / 180°
Period: min. 20 µs
Pulse width: min. 10 µs
Power Meter
Frequency range: 9 kHz – 1 GHz
Linear measurement range
channel 1: -15 dBm to +27 dBm
channel 2,3: -25 dBm to +20 dBm
Max. input/no damage
channel 1-3: +28 dBm
Noise level: >6 dB below the measurement range
Input return loss: >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
Connector: BNC socket, 50 O
Accuracy 150 kHz to 1 GHz, 10 to 30°C
channel 1 to 3: typ. channel 1, below 10 MHz: range >25 dBm typ. channel 2 and 3, below 10 MHz: range >17 dBm typ.
channel 1: -15 dBm to +27 dBm
channel 2,3: -25 dBm to +20 dBm
channel 1-3: +28 dBm
channel 1 to 3: typ. channel 1, below 10 MHz: range >25 dBm typ. channel 2 and 3, below 10 MHz: range >17 dBm typ.
Power Amplifier (75 Watt Version):
Frequency Range: 150 kHz - 230 MHz
Input Impedance: 50 O
Output Impedance: 50 O
Input Return Loss: min. 10 dB
Output Return Loss: nominal min. 9.5 dB, 0 dB without damage
Gain: min. 50 dB
Gain Flatness: max. +/- 3 dB
Saturated Output Power: min. 48.75 dBm
Max. input power linear without damage: < -3 dBm max. +10 dBm
If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.
Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.
VAT
Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated. Where VAT is charged, a rate of 23% is applied.