Keysight Technologies B2987A

Rohde & Schwarz URE3

Rohde & Schwarz URE3

ENI 350L

ENI 350L

Obtener cotización
Electrometer/High Resistance Meter, 0.01fA, Battery
Availability:
In stock
SKU
129392
Keysight B2987A (Agilent) ELECTROMETER / HIGH RESISTANCE METER The Keysight B2987A Electrometer / High Resistance Meter is designed with unprecedented capabilities and features guaranteeing outstanding measurement performance. It offers mimimum?cur resolution for meeting all low-level cur measurement needs and its voltage sourcing feature supports?resistance measurements. Its unique color LCD provides multiple options for viewing data. State-of-the-art front-panel capabilities allow you to capture transient behavior and perform quick statistical analyses without the need of a PC. The Agilent B2987A Meter features battery operation providing line noise free measurements.Features and Specifications of the Keysight B2987A (Agilent) Electrometer / High Resistance Meter include: ?Features: ?
  • Graphical capabilities:
  • Time domain view to capture transients
  • Histogram view to perform quick data analysis
  • Other X-Y plot (I-V, I-t, R-t, I-R, etc.)
  • Easy-to-use navigation to select optimal range and aperture
  • Optional Test Setup Integrity Checker function for noise source isolation
  • Battery operation for line noise free measurements
  • Versatile interface (USB 2.0: LAN, GPIB, LXI Core)
  • USB (front): store data, save/recall setup information
  • Temperature and humidity measurements
  • Free PC control software
  • Applications:
  • Material science (Biomaterials, ceramics, elastomers, films, dielectric materials, electrochemical, ferroelectric materials, graphene, metals, organic materials, nano-materials, polymers, semiconductors, etc.)
  • Devices & elecronic components (capacitors, resistors, diodes, sensors, transistors including TFT and CNT, optoelectronics, solar cells, etc.)
  • Electronic/non-electronic systems (ion beam, electron beam, sensing systems, particle measurements, embedded precision instruments, etc.)
  • Time domain view to capture transients
  • Histogram view to perform quick data analysis
  • Other X-Y plot (I-V, I-t, R-t, I-R, etc.)
  • Material science (Biomaterials, ceramics, elastomers, films, dielectric materials, electrochemical, ferroelectric materials, graphene, metals, organic materials, nano-materials, polymers, semiconductors, etc.)
  • Devices & elecronic components (capacitors, resistors, diodes, sensors, transistors including TFT and CNT, optoelectronics, solar cells, etc.)
  • Electronic/non-electronic systems (ion beam, electron beam, sensing systems, particle measurements, embedded precision instruments, etc.)
Specifications of the Keysight B2987A (Agilent) Electrometer / High Resistance Meter:
  • Measurement resolution: ?6? digits
  • Cur measurement: ?0.01 fA - 20 mA
  • Minimum range: ?2 pA
  • Resistance measurement: ?up to 10 P?
  • Voltage measurement: ?1 ?V - 20 V
  • Input resistance: ?> 200 T?
  • Charge measurement: ?1 fC - 2 ?C
  • Voltage source: ?up to ? 1,000 V
  • Minimum resolution: ?700 ?V
  • Maximum reading rate: ?20,000 rdg/s
  • < 20 ? V burden voltage in its lowest cur range
  • Voltage measurement:
  • Voltage range: 2 V
    • Display resolution: ?1 ?V
    • Accuracy ?(% + offset): ?0.025 + 40 ?V
  • Voltage range: 20 V
    • Display resolution: ?10 ?V
    • Accuracy ?(% + offset): ?0.025 + 400 ?V
  • Input bias cur: ?< 20 fA
  • Input impedance: ?> 200 T?, parallel with < 20 pF (non-guarded) or < 2 pF (guarded)
  • RMS noise: ?1.4 ?V for 2 V range, 10 s duration, shorted input
  • Measurement control / navigation:
  • Ranging: Automatic or manual
  • Aperture time (integration time): ?10 ?s to 100 PLC
  • Offset cancelling: ?Null, Zero correct
  • Digital filter: Medium filter (2R + 1, R = 1 to 15), moving average (1 to 100, step 1)
  • Math: ?Preset and user definable expressions
  • Statistics: ?Histogram View mode: mean, sigma, # of bins and # of samples
  • Line frequency detection: ?Auto detect: 50 Hz or 60 Hz
  • Front panel operation:
  • Front panel interface: ?4.3" TFT color display with keypads and rotary knob
  • View mode: Meter view, Graph view, Histogram view and Roll view
  • Hard keys: ?Single Trigger and Run/Stop control, measurement navigation keys, Rotary Knob and Cursors, Ammeter Input and V Source Output control, Cancel/Local
  • Soft keys: ?Function, System, and Input Assist Keys
  • Indicators: Channel (measurement) status, System status
  • LEDs:
    • Power (color changes when charging)
    • Input and Output (color changes when high voltage sourcing)
  • Input/Output specifications:
  • Meter input connector: ?Three lug triaxial for ammeter on rear panel
  • Maximum input:
    • Ammeter: 30 mA
    • Voltmeter: 40 V
  • Source output connector: ?Two banana jacks on rear panel
  • Maximum common mode voltage: ?Meter common: 500 V peak: V Source 1,000 V peak
  • Isolation (Meter common to chassis: ?> 10 G?, < 500 pF
  • Analog output: 2 V for full range input, non-inverting in voltage and cur measurement modes, 1 k? output impedance
  • Interlock: ?2.5 mm pluggable terminal block, 4 pin
  • External trigger:
    • Trigger input: ?BNC
      • Logic: ?Programmable edge triggered
      • Min pulse width: ?10 ?s
    • Trigger output: ?BNC
      • Logic: ?Programmable edge triggered
      • Min pulse width: ?10 ?s
  • Digital I/O:
    • Connector type: ?DSUB female 9 pins
    • Input/output pins: ?DIO 7 pins, +5V, GND
    • Absolute ?max input voltage: ?5.25 V
    • Absolute ?min input voltage: ?-0.25 V
    • Max logic L input voltage: ?-0.8 V, Pull-up to 5 V by 5 k?
    • Min logic H input voltage: ?2.0 V, Pull-up to 5 V by 5 k?
    • Max source cur: ?1 mA @ Vo = 0 V
    • Max sink cur: ?50 mA @ Vo = 5 V
    • 5 V power supply pin: ?Limited to 500 mA, resettable fuse protected
  • Minimum range: ?2 pA
  • Input resistance: ?> 200 T?
  • Minimum resolution: ?700 ?V
  • Voltage range: 2 V
  • Display resolution: ?1 ?V
  • Accuracy ?(% + offset): ?0.025 + 40 ?V
  • Voltage range: 20 V
  • Display resolution: ?10 ?V
  • Accuracy ?(% + offset): ?0.025 + 400 ?V
  • Display resolution: ?1 ?V
  • Accuracy ?(% + offset): ?0.025 + 40 ?V
  • Display resolution: ?10 ?V
  • Accuracy ?(% + offset): ?0.025 + 400 ?V
  • Ranging: Automatic or manual
  • Aperture time (integration time): ?10 ?s to 100 PLC
  • Offset cancelling: ?Null, Zero correct
  • Digital filter: Medium filter (2R + 1, R = 1 to 15), moving average (1 to 100, step 1)
  • Math: ?Preset and user definable expressions
  • Statistics: ?Histogram View mode: mean, sigma, # of bins and # of samples
  • Line frequency detection: ?Auto detect: 50 Hz or 60 Hz
  • Front panel interface: ?4.3" TFT color display with keypads and rotary knob
  • View mode: Meter view, Graph view, Histogram view and Roll view
  • Hard keys: ?Single Trigger and Run/Stop control, measurement navigation keys, Rotary Knob and Cursors, Ammeter Input and V Source Output control, Cancel/Local
  • Soft keys: ?Function, System, and Input Assist Keys
  • Indicators: Channel (measurement) status, System status
  • LEDs:
  • Power (color changes when charging)
  • Input and Output (color changes when high voltage sourcing)
  • Power (color changes when charging)
  • Input and Output (color changes when high voltage sourcing)
  • Meter input connector: ?Three lug triaxial for ammeter on rear panel
  • Maximum input:
  • Ammeter: 30 mA
  • Voltmeter: 40 V
  • Source output connector: ?Two banana jacks on rear panel
  • Maximum common mode voltage: ?Meter common: 500 V peak: V Source 1,000 V peak
  • Isolation (Meter common to chassis: ?> 10 G?, < 500 pF
  • Analog output: 2 V for full range input, non-inverting in voltage and cur measurement modes, 1 k? output impedance
  • Interlock: ?2.5 mm pluggable terminal block, 4 pin
  • External trigger:
  • Trigger input: ?BNC
    • Logic: ?Programmable edge triggered
    • Min pulse width: ?10 ?s
  • Trigger output: ?BNC
    • Logic: ?Programmable edge triggered
    • Min pulse width: ?10 ?s
  • Digital I/O:
  • Connector type: ?DSUB female 9 pins
  • Input/output pins: ?DIO 7 pins, +5V, GND
  • Absolute ?max input voltage: ?5.25 V
  • Absolute ?min input voltage: ?-0.25 V
  • Max logic L input voltage: ?-0.8 V, Pull-up to 5 V by 5 k?
  • Min logic H input voltage: ?2.0 V, Pull-up to 5 V by 5 k?
  • Max source cur: ?1 mA @ Vo = 0 V
  • Max sink cur: ?50 mA @ Vo = 5 V
  • 5 V power supply pin: ?Limited to 500 mA, resettable fuse protected
  • Ammeter: 30 mA
  • Voltmeter: 40 V
  • Trigger input: ?BNC
  • Logic: ?Programmable edge triggered
  • Min pulse width: ?10 ?s
  • Trigger output: ?BNC
  • Logic: ?Programmable edge triggered
  • Min pulse width: ?10 ?s
  • Logic: ?Programmable edge triggered
  • Min pulse width: ?10 ?s
  • Logic: ?Programmable edge triggered
  • Min pulse width: ?10 ?s
  • Connector type: ?DSUB female 9 pins
  • Input/output pins: ?DIO 7 pins, +5V, GND
  • Absolute ?max input voltage: ?5.25 V
  • Absolute ?min input voltage: ?-0.25 V
  • Max logic L input voltage: ?-0.8 V, Pull-up to 5 V by 5 k?
  • Min logic H input voltage: ?2.0 V, Pull-up to 5 V by 5 k?
  • Max source cur: ?1 mA @ Vo = 0 V
  • Max sink cur: ?50 mA @ Vo = 5 V
  • 5 V power supply pin: ?Limited to 500 mA, resettable fuse protected
????
More Information
Model B2987A

Shipping

Shipping is free within the EU and UK. For destinations outside these regions, a fixed cost of €290 applies.

Returns

If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.

Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.

VAT

Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated.
Where VAT is charged, a rate of 23% is applied.

VAT is not charged outside of the EU.