Haefely PCD130 The Haefely PCD130 CDN, as part of the PSURGE 8000 system is tailored to meet IEC and EN standards to cover testing of 3 phase AC and DC power ports. These standards include recommendations for the coupling and decoupling component values within the CDN. These values are largely based on the European model for AC power lines. PCD 130 includes all the IEC and EN requirements with automatic coupling path switching. PCD 130 EUT output has specially designed 4mm connectors, which provide enhanced personnel safety in relation to the high voltage impulse.ANSI / IEEE standards are the reference for power line tests in many American standards such as TIA-968-A (FCC part 68) and Telcordia (Bellcore) GR-1089-CORE. The ANSI standard contains much the same information as the IEC but based around the American experience with AC power lines.Impedance of the low voltage mains supply to earth is simulated by the addition of a 10 ohm resistor for IEC tests. ANSI has NO series resistor in the impulse path This difference comes from the practice in Europe of connecting ground to neutral at the distribution transformer, not the power service entry as in the USA. The Haefely PCD 130 automatically sets the correct coupling elements for either IEC or ANSI as selected by the user.The integration in the WinFEAT&R control and reporting software package enhances an efficient set-up and operation of the Haefely PCD130. Most importantly, the test load can be transferred to a computer freeing valuable resources.Features of the Haefely PCD130 3-Phase Coupling / Decoupling Network include:
Three high voltage inputs
Combination wave 1.2/50us - 8/20us
Ring wave 100kHz
8kV impulse voltage
Line voltage 690Vac phase-phase
32A EUT Cur per phase
Phase angle synchronization for each path
Highlights of the Haefely PCD130 include:
International application – Specifically designed to meet and exceed the requirements of IEC, EN, and ANSI tests for power line applications.
Synchronization path Switching - The PCD 130 synchronizes impulses with the selected coupling path. Safe and Easy - The interlocked HV connections allow your operators to test safely and easily.
Full 32A capability – Both AC and DC loads up to 32A per phase can be connected through the PCD 130.
Sturdy and Reliable – Careful component selection ensures that the PCD 130 will continue to operate under the most strenuous testing regime.
Faster completion of testing program - The PCD 130 has 3 multiplexed inputs, enabling testing to continue with other pulses without having to remove power from the EUT.
Applications include:
Single & Three phase power line systems
IEC 61000-4-5 Edition 1 & 2 Power line testing
IEC 61000-4-12 Power line testing
ANSI C62.41 & C62.45 Power lines
Many IEC & EN Product standards
Specifications of the Haefely PCD130 include:
Maximum Impulse Voltage 8kV
Maximum AC Voltage 690VRMS (Phase – Phase)
Maximum DC Voltage 110V
Maximum AC Cur 32ARMS
Maximum DC Cur 32A
Residual voltage at Test supply input max. 15% of the applied impulse voltage
EUT Connections 4mm HV Safety sockets
Phase Sync. Follows coupling path
Phase Sync accuracy ±1°
Coupling Elements and paths Controlled by the PSURGE 8000
Power Supply 85 – 264V 50/60Hz
Voltage drop due to the decoupling inductors +/- 10% with max. cur and cos f +/- 0.7
If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.
Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.
VAT
Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated. Where VAT is charged, a rate of 23% is applied.