Rohde & Schwarz FSVR7 REAL-TIME SPECTRUM Analyser The full-featured Rohde & Schwarz (R&S) FSVR7 Real-Time Spectrum Analyser is the combination of a signal and spectrum Analyser and a real-time spectrum Analyser. In real-time operation the FSVR7 seamlessly measures and displays the spectrum in the time domain, with a span of up to 40 MHz, capturing every event, no matter how brief, for analysis.Features and Specifications of the Rohde & Schwarz FSVR7 Real-Time Spectrum Analyser include:Features of the R&S FSVR7 Analyser:
Real-time spectrum analysis up to 40 GHz:
Spectrogram function for gapless spectrum display in the time domain
Frequency mask trigger (FMT) for triggering the measurement by individual, sporadic events in the spectrum
Persistence mode for visualizing how frequently signals occur
Power versus time for analyzing the length/time variance of signals
Real-time streaming of I/Q data for recording long RF sequences
Full-featured signal and spectrum Analyser:
Frequency sweep across the entire frequency range from 10 Hz to 40 GHz in just a few milliseconds
Expansion of the maximum input frequency of 110 GHz using external mixers
Outstanding level measurement accuracy up to 7 GHz
Excellent dynamic range and low phase noise
High measurement speed
Power measurement functions and statistical evaluations for analysis of digitally modulated signals
Versatile marker and trace evaluation functions
Measurement software for determining noise figure or phase noise
General vector signal analysis (VSA) and special analysis options for GSM/EDGE, WCDMA/HSPA+, LTE, WiMAX™, WLAN as well as analog modulation methods
Large I/Q memory depth
Simple and intuitive operation by means of touch screen:
Touch-screen operation using the finger as a mouse cursor
Fast access to all important functions
Built-in help function
Undo/redo function
Spectrogram function for gapless spectrum display in the time domain
Frequency mask trigger (FMT) for triggering the measurement by individual, sporadic events in the spectrum
Persistence mode for visualizing how frequently signals occur
Power versus time for analyzing the length/time variance of signals
Real-time streaming of I/Q data for recording long RF sequences
Frequency sweep across the entire frequency range from 10 Hz to 40 GHz in just a few milliseconds
Expansion of the maximum input frequency of 110 GHz using external mixers
Outstanding level measurement accuracy up to 7 GHz
Excellent dynamic range and low phase noise
High measurement speed
Power measurement functions and statistical evaluations for analysis of digitally modulated signals
Versatile marker and trace evaluation functions
Measurement software for determining noise figure or phase noise
General vector signal analysis (VSA) and special analysis options for GSM/EDGE, WCDMA/HSPA+, LTE, WiMAX™, WLAN as well as analog modulation methods
Large I/Q memory depth
Touch-screen operation using the finger as a mouse cursor
Fast access to all important functions
Built-in help function
Undo/redo function
Specifications of the Rohde & Schwarz FSVR7 Real-Time Spectrum Analyser:
Frequency:
Frequency range: 10 Hz to 7 GHz
Aging of frequency reference: 1 x 10-6
With R&S®FSV-B4: 1 x 10-7
Real-time spectrum Analyser:
Real-time RF bandwidth: 100 Hz to 40 MHz
A/D converter: 128 Msamples/s, 16 bit
Windowing: Blackman Harris, Gauss, flat top, rectangular, Hanning, Kaiser
Measurement points per trace: 801
Resolution bandwidth: real-time RF bandwidth/(100 to 400), depending on windowing
Number of spectra per second: 250 000/s
Spectrogram update rate: 10 000/s
Screen update rate: 30/s
Detectors: Average (linear or RMS), Max Peak, Min Peak, Sample
Trace functions: Max Hold, Min Hold, Average
Frequency Mask Trigger (FMT):
Frequency resolution: Real-time bandwidth/801
Trigger span: Real-time RF bandwidth
Dynamic range: 0 dB to -80 dB below reference level
Spectrum Analyser:
Bandwidths:
Resolution bandwidths:
Standard filter: 1 Hz to 10 MHz
Standard filter, ZERO SPAN: 1 Hz to 10 MHz, 20 MHz, 40 MHz
FFT sweep: 1 Hz to 300 kHz
Channel filter: 100 Hz to 5 MHz
Video filter: 1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
I/Q demodulation bandwidth: 40 MHz
40 GHz -165 dBm (1 Hz) typical
Displayed average noise level:
Displayed average noise level:
1 GHz -152 dBm (1 Hz)
30 GHz -150 dBm
Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option:
1 GHz -163 dBm
30 GHz -162 dBm
Intermodulation:
Third-order intercept (TOI): f < 3.6 GHz - 16 dBm
WCDMA ACLR:
Without noise compensation: 70 dB
With noise compensation: 73 dB
Phase noise:
1 GHz carrier frequency:
10 kHz offset from carrier: -106 dBc (1 Hz)
100 kHz offset from carrier: -115 dBc (1 Hz)
1 MHz offset from carrier: -134 dBc (1 Hz)
Total measurement uncertainty: f < 7 GHz - 0.4 dBm
Frequency range: 10 Hz to 7 GHz
Aging of frequency reference: 1 x 10-6
With R&S®FSV-B4: 1 x 10-7
With R&S®FSV-B4: 1 x 10-7
Real-time RF bandwidth: 100 Hz to 40 MHz
A/D converter: 128 Msamples/s, 16 bit
Windowing: Blackman Harris, Gauss, flat top, rectangular, Hanning, Kaiser
Measurement points per trace: 801
Resolution bandwidth: real-time RF bandwidth/(100 to 400), depending on windowing
Number of spectra per second: 250 000/s
Spectrogram update rate: 10 000/s
Screen update rate: 30/s
Detectors: Average (linear or RMS), Max Peak, Min Peak, Sample
Trace functions: Max Hold, Min Hold, Average
Frequency resolution: Real-time bandwidth/801
Trigger span: Real-time RF bandwidth
Dynamic range: 0 dB to -80 dB below reference level
Bandwidths:
Resolution bandwidths:
Standard filter: 1 Hz to 10 MHz
Standard filter, ZERO SPAN: 1 Hz to 10 MHz, 20 MHz, 40 MHz
FFT sweep: 1 Hz to 300 kHz
Channel filter: 100 Hz to 5 MHz
Video filter: 1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
I/Q demodulation bandwidth: 40 MHz
40 GHz -165 dBm (1 Hz) typical
Displayed average noise level:
Displayed average noise level:
1 GHz -152 dBm (1 Hz)
30 GHz -150 dBm
Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option:
1 GHz -163 dBm
30 GHz -162 dBm
Intermodulation:
Third-order intercept (TOI): f < 3.6 GHz - 16 dBm
WCDMA ACLR:
Without noise compensation: 70 dB
With noise compensation: 73 dB
Phase noise:
1 GHz carrier frequency:
10 kHz offset from carrier: -106 dBc (1 Hz)
100 kHz offset from carrier: -115 dBc (1 Hz)
1 MHz offset from carrier: -134 dBc (1 Hz)
Total measurement uncertainty: f < 7 GHz - 0.4 dBm
Resolution bandwidths:
Standard filter: 1 Hz to 10 MHz
Standard filter, ZERO SPAN: 1 Hz to 10 MHz, 20 MHz, 40 MHz
FFT sweep: 1 Hz to 300 kHz
Channel filter: 100 Hz to 5 MHz
Video filter: 1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
I/Q demodulation bandwidth: 40 MHz
40 GHz -165 dBm (1 Hz) typical
Standard filter: 1 Hz to 10 MHz
Standard filter, ZERO SPAN: 1 Hz to 10 MHz, 20 MHz, 40 MHz
FFT sweep: 1 Hz to 300 kHz
Channel filter: 100 Hz to 5 MHz
Displayed average noise level:
1 GHz -152 dBm (1 Hz)
30 GHz -150 dBm
Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option:
Shipping is free within the EU and UK. For destinations outside these regions, a fixed cost of €290 applies.
Returns
If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.
Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.
VAT
Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated. Where VAT is charged, a rate of 23% is applied.