Rohde & Schwarz FSVR7

Model

FSVR7

Product

Real-Time Spectrum Analyser, 7 GHz
0,00 €
Availability:
In stock
SKU
138264
Rohde & Schwarz FSVR7 REAL-TIME SPECTRUM Analyser The full-featured Rohde & Schwarz (R&S) FSVR7 Real-Time Spectrum Analyser is the combination of a signal and spectrum Analyser and a real-time spectrum Analyser. In real-time operation the FSVR7 seamlessly measures and displays the spectrum in the time domain, with a span of up to 40 MHz, capturing every event, no matter how brief, for analysis.Features and Specifications of the Rohde & Schwarz FSVR7 Real-Time Spectrum Analyser include:Features of the R&S FSVR7 Analyser:
  • Real-time spectrum analysis up to 40 GHz:
    • Spectrogram function for gapless spectrum display in the time domain
    • Frequency mask trigger (FMT) for triggering the measurement by individual, sporadic events in the spectrum
    • Persistence mode for visualizing how frequently signals occur
    • Power versus time for analyzing the length/time variance of signals
    • Real-time streaming of I/Q data for recording long RF sequences
  • Full-featured signal and spectrum Analyser:
    • Frequency sweep across the entire frequency range from 10 Hz to 40 GHz in just a few milliseconds
    • Expansion of the maximum input frequency of 110 GHz using external mixers
    • Outstanding level measurement accuracy up to 7 GHz
    • Excellent dynamic range and low phase noise
    • High measurement speed
    • Power measurement functions and statistical evaluations for analysis of digitally modulated signals
    • Versatile marker and trace evaluation functions
    • Measurement software for determining noise figure or phase noise
    • General vector signal analysis (VSA) and special analysis options for GSM/EDGE, WCDMA/HSPA+, LTE, WiMAX™, WLAN as well as analog modulation methods 
    • Large I/Q memory depth
  • Simple and intuitive operation by means of touch screen:
    • Touch-screen operation using the finger as a mouse cursor
    • Fast access to all important functions 
    • Built-in help function
    • Undo/redo function
  • Spectrogram function for gapless spectrum display in the time domain
  • Frequency mask trigger (FMT) for triggering the measurement by individual, sporadic events in the spectrum
  • Persistence mode for visualizing how frequently signals occur
  • Power versus time for analyzing the length/time variance of signals
  • Real-time streaming of I/Q data for recording long RF sequences
  • Frequency sweep across the entire frequency range from 10 Hz to 40 GHz in just a few milliseconds
  • Expansion of the maximum input frequency of 110 GHz using external mixers
  • Outstanding level measurement accuracy up to 7 GHz
  • Excellent dynamic range and low phase noise
  • High measurement speed
  • Power measurement functions and statistical evaluations for analysis of digitally modulated signals
  • Versatile marker and trace evaluation functions
  • Measurement software for determining noise figure or phase noise
  • General vector signal analysis (VSA) and special analysis options for GSM/EDGE, WCDMA/HSPA+, LTE, WiMAX™, WLAN as well as analog modulation methods 
  • Large I/Q memory depth
  • Touch-screen operation using the finger as a mouse cursor
  • Fast access to all important functions 
  • Built-in help function
  • Undo/redo function
  • Specifications of the Rohde & Schwarz FSVR7 Real-Time Spectrum Analyser:
  • Frequency:
    • Frequency range: 10 Hz to 7 GHz
    • Aging of frequency reference:  1 x 10-6
      • With R&S®FSV-B4:  1 x 10-7 
  • Real-time spectrum Analyser:
    • Real-time RF bandwidth:  100 Hz to 40 MHz
    • A/D converter:  128 Msamples/s, 16 bit
    • Windowing:  Blackman Harris, Gauss, flat top, rectangular, Hanning, Kaiser
    • Measurement points per trace:  801  
    • Resolution bandwidth:  real-time RF bandwidth/(100 to 400), depending on windowing
    • Number of spectra per second:  250 000/s
    • Spectrogram update rate:  10 000/s
    • Screen update rate:  30/s
    • Detectors:  Average (linear or RMS), Max Peak, Min Peak, Sample
    • Trace functions:  Max Hold, Min Hold, Average
  • Frequency Mask Trigger (FMT):
    • Frequency resolution:  Real-time bandwidth/801
    • Trigger span:  Real-time RF bandwidth
    • Dynamic range:  0 dB to -80 dB below reference level
  • Spectrum Analyser:
    • Bandwidths:
      • Resolution bandwidths:  
        • Standard filter:  1 Hz to 10 MHz
        • Standard filter, ZERO SPAN:  1 Hz to 10 MHz, 20 MHz, 40 MHz
        • FFT sweep:  1 Hz to 300 kHz
        • Channel filter:   100 Hz to 5 MHz
      • Video filter:  1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
      • I/Q demodulation bandwidth:  40 MHz
      • 40 GHz -165 dBm (1 Hz) typical
    • Displayed average noise level:  
      • Displayed average noise level: 
        • 1 GHz -152 dBm (1 Hz)
        • 30 GHz -150 dBm
      • Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option: 
        • 1 GHz -163 dBm
        • 30 GHz -162 dBm 
    • Intermodulation:
      • Third-order intercept (TOI):  f < 3.6 GHz - 16 dBm
    • WCDMA ACLR:
      • Without noise compensation:  70 dB
      • With noise compensation: 73 dB
    • Phase noise:
      • 1 GHz carrier frequency:  
        • 10 kHz offset from carrier: -106 dBc (1 Hz)  
        • 100 kHz offset from carrier: -115 dBc (1 Hz)
        • 1 MHz offset from carrier: -134 dBc (1 Hz)
    • Total measurement uncertainty:   f < 7 GHz - 0.4 dBm
  • Frequency range: 10 Hz to 7 GHz
  • Aging of frequency reference:  1 x 10-6
    • With R&S®FSV-B4:  1 x 10-7 
  • With R&S®FSV-B4:  1 x 10-7 
  • Real-time RF bandwidth:  100 Hz to 40 MHz
  • A/D converter:  128 Msamples/s, 16 bit
  • Windowing:  Blackman Harris, Gauss, flat top, rectangular, Hanning, Kaiser
  • Measurement points per trace:  801  
  • Resolution bandwidth:  real-time RF bandwidth/(100 to 400), depending on windowing
  • Number of spectra per second:  250 000/s
  • Spectrogram update rate:  10 000/s
  • Screen update rate:  30/s
  • Detectors:  Average (linear or RMS), Max Peak, Min Peak, Sample
  • Trace functions:  Max Hold, Min Hold, Average
  • Frequency resolution:  Real-time bandwidth/801
  • Trigger span:  Real-time RF bandwidth
  • Dynamic range:  0 dB to -80 dB below reference level
  • Bandwidths:
    • Resolution bandwidths:  
      • Standard filter:  1 Hz to 10 MHz
      • Standard filter, ZERO SPAN:  1 Hz to 10 MHz, 20 MHz, 40 MHz
      • FFT sweep:  1 Hz to 300 kHz
      • Channel filter:   100 Hz to 5 MHz
    • Video filter:  1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
    • I/Q demodulation bandwidth:  40 MHz
    • 40 GHz -165 dBm (1 Hz) typical
  • Displayed average noise level:  
    • Displayed average noise level: 
      • 1 GHz -152 dBm (1 Hz)
      • 30 GHz -150 dBm
    • Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option: 
      • 1 GHz -163 dBm
      • 30 GHz -162 dBm 
  • Intermodulation:
    • Third-order intercept (TOI):  f < 3.6 GHz - 16 dBm
  • WCDMA ACLR:
    • Without noise compensation:  70 dB
    • With noise compensation: 73 dB
  • Phase noise:
    • 1 GHz carrier frequency:  
      • 10 kHz offset from carrier: -106 dBc (1 Hz)  
      • 100 kHz offset from carrier: -115 dBc (1 Hz)
      • 1 MHz offset from carrier: -134 dBc (1 Hz)
  • Total measurement uncertainty:   f < 7 GHz - 0.4 dBm
  • Resolution bandwidths:  
    • Standard filter:  1 Hz to 10 MHz
    • Standard filter, ZERO SPAN:  1 Hz to 10 MHz, 20 MHz, 40 MHz
    • FFT sweep:  1 Hz to 300 kHz
    • Channel filter:   100 Hz to 5 MHz
  • Video filter:  1 Hz to 10 MHz, 20 MHz, 28 MHz, 40 MHz
  • I/Q demodulation bandwidth:  40 MHz
  • 40 GHz -165 dBm (1 Hz) typical
  • Standard filter:  1 Hz to 10 MHz
  • Standard filter, ZERO SPAN:  1 Hz to 10 MHz, 20 MHz, 40 MHz
  • FFT sweep:  1 Hz to 300 kHz
  • Channel filter:   100 Hz to 5 MHz
  • Displayed average noise level: 
    • 1 GHz -152 dBm (1 Hz)
    • 30 GHz -150 dBm
  • Displayed average noise level with preamplifier, R&SFSV-B22 or R&SFSV-B24 option: 
    • 1 GHz -163 dBm
    • 30 GHz -162 dBm 
  • 1 GHz -152 dBm (1 Hz)
  • 30 GHz -150 dBm
  • 1 GHz -163 dBm
  • 30 GHz -162 dBm 
  • Third-order intercept (TOI):  f < 3.6 GHz - 16 dBm
  • Without noise compensation:  70 dB
  • With noise compensation: 73 dB
  • 1 GHz carrier frequency:  
    • 10 kHz offset from carrier: -106 dBc (1 Hz)  
    • 100 kHz offset from carrier: -115 dBc (1 Hz)
    • 1 MHz offset from carrier: -134 dBc (1 Hz)
  • 10 kHz offset from carrier: -106 dBc (1 Hz)  
  • 100 kHz offset from carrier: -115 dBc (1 Hz)
  • 1 MHz offset from carrier: -134 dBc (1 Hz)
  •     

    Shipping

    Shipping is free within the EU and UK. For destinations outside these regions, a fixed cost of €290 applies.

    Returns

    If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.

    Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.

    VAT

    Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated.
    Where VAT is charged, a rate of 23% is applied.

    VAT is not charged outside of the EU.