SORENSEN SGI800-12.5 DC Power Supply, 800V, 12.5A, 10kW (call for availability)The Sorensen SGI800-12.5 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.The Sorensen SGI800-12.5 DC Power Supply (SGI = Sorensen General Purpose Intelligent) combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the Sorensen SGI800-12.5 DC Power Supply ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the Sorensen SGI800-12.5 DC Power Supply. Features and Specifications of the Sorensen SGA800-12.5 DC Power Supply include:
High Power Density: Up to 15 kW in a 3U chassis
Wide Voltage Range: 0-10V up to 0-800V, in increments of 5 kW from 5 to 30 kW
Fast Load Transient Response: Protection from undesired voltage excursions
Low RMS and P-P Noise: Suitable for the most sensitive applications
Parallelable up to 150 kW: Expandable as your requirement grows
Modular Design: Upgradeable for the ultimate in investment protection
Sequencing: Program custom waveforms
Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
Ethernet Control: LXI Class C compliant communication through integrated web server
Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
Hardware Trigger: Ethernet Option Only
Common:
Remote Sense: Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply).
Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
Series Operation: Up to 2 units
Input:
Nominal Voltage 3 phase, 3 wire + ground:
- 208/220 VAC (operating range 187 – 242 VAC)
- 380/400 VAC (operating range 342 – 440 VAC)
- 440/480 VAC (operating range 396 – 528 VAC)
Frequency: 47 – 63Hz , 400Hz
Power Factor:
- >0.9 typical for 208/220 VAC input (10V – 800V)
- >0.78 typical for 380/400 VAC input (40V – 800V)
- >0.9 typical for 380/480 VAC input (10V – 30V)
- >0.7 typical for 440/480 VAC input (40V – 800V)
- >0.9 typical for 440/480 VAC input (10V – 30V)
Protection: ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
- 208/220 VAC (operating range 187 – 242 VAC)
- 380/400 VAC (operating range 342 – 440 VAC)
- 440/480 VAC (operating range 396 – 528 VAC)
208/220 VAC (operating range 187 – 242 VAC)
380/400 VAC (operating range 342 – 440 VAC)
440/480 VAC (operating range 396 – 528 VAC)
- >0.9 typical for 208/220 VAC input (10V – 800V)
- >0.78 typical for 380/400 VAC input (40V – 800V)
- >0.9 typical for 380/480 VAC input (10V – 30V)
- >0.7 typical for 440/480 VAC input (40V – 800V)
- >0.9 typical for 440/480 VAC input (10V – 30V)
>0.9 typical for 208/220 VAC input (10V – 800V)
>0.78 typical for 380/400 VAC input (40V – 800V)
>0.9 typical for 380/480 VAC input (10V – 30V)
>0.7 typical for 440/480 VAC input (40V – 800V)
>0.9 typical for 440/480 VAC input (10V – 30V)
Output:
Voltage and Cur Range: 800V, 12.5A, 10kW
Ripple & Noise:
- rms(20Hz-300kHz): 80mV
- p-p: 500mV
- rms(20Hz-300kHz): 80mV
- p-p: 500mV
rms(20Hz-300kHz): 80mV
p-p: 500mV
Programming & Read-Back Specifications:
Front Panel Display:
- Programming:
- Accuracy:
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
- Resolution: 4.0 digits
- Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: 4.0 digits
- Knob control & Display read-back
Remote Analog Interface:
- Programming:
- Accuracy:
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
- Read-Back Monitoring:
- Accuracy: (40-800V) +/-1.0% of full scale
- 25-pin D-sub connector (0~5 V or 0~10 V)
Remote Digital Interface:
- Programming:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
- RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
OVP:
- Programming:
- Accuracy: +/- 1% of full scale
- Resolution: +/-0.002% of full scale
- Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
User I/O:
- Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
Programming:
- Accuracy:
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
- Resolution: 4.0 digits
Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: 4.0 digits
Knob control & Display read-back
Accuracy:
- (40-800V) +/- 0.1% of voltage at full scale
- (40-800V) +/- 0.4% of cur at full scale
Resolution: 4.0 digits
(40-800V) +/- 0.1% of voltage at full scale
(40-800V) +/- 0.4% of cur at full scale
Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
Resolution: 4.0 digits
Voltage: +/- 0.1% of full scale
Cur: +/- 0.4% of full scale
Programming:
- Accuracy:
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
Read-Back Monitoring:
- Accuracy: (40-800V) +/-1.0% of full scale
25-pin D-sub connector (0~5 V or 0~10 V)
Accuracy:
- Voltage: +/-0.25% of full scale
- Cur: (40-800V) 0.8% of full scale
Voltage: +/-0.25% of full scale
Cur: (40-800V) 0.8% of full scale
Accuracy: (40-800V) +/-1.0% of full scale
Programming:
- Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
Read-Back Monitoring:
- Accuracy:
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
- Resolution: +/-0.002% of full scale
RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
Accuracy:
- Voltage: +/- 0.1% of full scale
- Cur: +/- 0.4% of full scale
Resolution: +/-0.002% of full scale
Voltage: +/- 0.1% of full scale
Cur: +/- 0.4% of full scale
Accuracy:
- Voltage: +/- 0.15% of full scale
- Cur: +/- 0.4% of full scale
Resolution: +/-0.002% of full scale
Voltage: +/- 0.15% of full scale
Cur: +/- 0.4% of full scale
Programming:
- Accuracy: +/- 1% of full scale
- Resolution: +/-0.002% of full scale
Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
Accuracy: +/- 1% of full scale
Resolution: +/-0.002% of full scale
Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
Product Overview Sorensen SGI800-13 (call for availability) The Sorensen SGI800-13 is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI800-13 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI800-13 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI800-13.Features of the Sorensen SGI800-13 include:
High Power Density: 10kW in a 3U chassis
Wide Voltage Range: 0-800V and 0-13 Amps
Fast Load Transient Response: Protection from undesired voltage excursions
Low RMS and P-P Noise: Suitable for the most sensitive applications
Parallelable up to 150 kW: Expandable as your requirement grows
Modular Design: Upgradeable for the ultimate in investment protection
Sequencing: Program custom waveforms
Easy-to-read Fluorescent Display: Supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
Ethernet Control: LXI Class C compliant communication through integrated web server
Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
Hardware Trigger: Ethernet Option Only
Specifications of the Sorensen SGI800-13 include:Common:
Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
Series Operation: Up to 2 units (see Output Float Voltage)
Input:
Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 – 242 VAC); 380/400 VAC (operating range 342 – 440 VAC); and 440/480 VAC (operating range 396 – 528 VAC)
Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and >0.69 typical at 440/480 VAC input
Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
Environmental:
Operating Temperature: 0 to 50º C
Storage Temperature: -25º C to 65º C
Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
Front Panel Dust Filter: 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature. 3U unit only.
Physical:
Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
Weight: 3U < 80 lbs. (36 kg) 6U
Output:
Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
Ripple (Cur Mode): <+/- 0.04% of full scale rms cur
DC Voltage Slew Rate: 45A / ms typical – resistive load
Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale
Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale
Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
Efficiency: 87% typical at nominal line and max load
Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point
Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur.
Programming Specifications of the Sorensen SGI800-13 include:Front Panel Display:
Voltage Accuracy: +/- 0.1% of full scale
Cur Accuracy: +/- 0.4% of full scale
Resolution: 4.0 digits
Remote Analog Interface:
Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
Cur Accuracy: 0.8% of full scale
Remote Digital Interface:
Voltage Accuracy: +/- 0.1% of full scale
Cur Accuracy: +/- 0.4% of full scale
Resolution: +/-0.002% of full scale
OVP:
Accuracy: +/- 1% of full scale
Resolution: +/-0.002% of full scale
User I/O:
Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
Read-Back / Monitoring Specifications of the Sorensen SGI800-13 include:Front Panel Display:
Voltage Accuracy: +/- 0.1% of full scale
Cur Accuracy: +/- 0.4% of full scale
Resolution: 4.0 digits
Remote Analog Interface:
Accuracy: +/-1.0% of full scale (0 – 10V)
Remote Digital Interface:
Voltage Accuracy: +/- 0.1% of full scale
Cur Accuracy: +/- 0.4% of full scale
Resolution: +/-0.002% of full scale
User I/O: