Sorensen SGI600-25

Gleichstromversorgung, 600 V, 25 A, 15 kW

Hersteller:
Modell: Sorensen SGI600-25
Beschreibung: Gleichstromversorgung, 600 V, 25 A, 15 kW
Datenblatt PDF: Sorensen SGI600-25

The SGe is an economical, FET based, high switching speed, programmable, dc power supply alternative to SCR and IGBT based dc supplies.Most topologies use either a MosFET or IGBT approach within their power stage to execute their power conversion topology. At the same time end users value low output ripple and noise in conjunction with achieving high slew rates. Both IGBT and SCR based designs typically run at much lower switching speeds requiring a larger LC output filter design for similar performance or require degrading ripple and noise performance in order to maintain competitive power densities. The filter design in this case may be balanced to trade off performance of response time with output ripple and noise and densities.In contrast, our SGe line leverages the benefits of using high switching speed Mosfets requiring a much smaller output stage LC filter in order to provide competitive output ripple and noise performance and response time without compromising power densities. Available in two control versions, the SGe has basic analog controls, while the SGI provides intelligent control featuresSGe: Real Value – Analog Control The SGe, with its outstanding FET based power electronics, is available for customers requiring simple front panel analog controls or external control. With high performance power electronics the SGe provides essential features like 10- turn potentiometers for setting voltage and cur, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.     

  • 1C – Ethernet + RS-S232C
  • C – Input Voltage 187 / 242VAC Standard
  • MSRP: $9,903 | Available for al      
  • Product Overview Sorensen SGI600-17 (call for availability) The Sorensen SGI600-17  is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI600-17 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI600-17 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI600-17.Features of the Sorensen SGI600-17 include:

  • High Power Density: 10kW in a 3U chassis
  • Wide Voltage Range: 0-600V and 0-17 Amps
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • Sequencing: Program custom waveforms
  • Easy-to-read Fluorescent Display: Supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only 
  • Specifications of the Sorensen SGI600-17 include:Common:

  • Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
  • Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
  • Series Operation: Up to 2 units (see Output Float Voltage)
  • Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 – 242 VAC); 380/400 VAC (operating range 342 – 440 VAC); and 440/480 VAC (operating range 396 – 528 VAC)
  • Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
  • Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and  >0.69 typical at 440/480 VAC input
  • Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
  • Environmental:

  • Operating Temperature: 0 to 50º C
  • Storage Temperature: -25º C to 65º C
  • Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
  • Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
  • Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
  • Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
  • Front Panel Dust Filter: 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature. 3U unit only.
  • Physical:

  • Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
  • Weight: 3U < 80 lbs. (36 kg) 6U
  • Output:

  • Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
  • Ripple (Cur Mode): <+/- 0.04% of full scale rms cur
  • DC Voltage Slew Rate: 45A / ms typical – resistive load
  • Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale
  • Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale
  • Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
  • Efficiency: 87% typical at nominal line and max load
  • Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
  • Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point
  • Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur.
  • Programming Specifications of the Sorensen SGI600-17 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
  • Cur Accuracy: 0.8% of full scale
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • OVP:

  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Read-Back / Monitoring Specifications of the Sorensen SGI600-17 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Accuracy: +/-1.0% of full scale (0 – 10V)
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •     

  • 1A – IEEE-488.2 + RS232C
  • C – Input Voltage 187 / 242VAC Standard
  • MSRP: $13,250 | Available for al      
  • Product Overview Sorensen SGI600-25 (call for availability) The Sorensen SGI600-25  is a Programmable Precision High Power DC Power Supply that is designed for exceptional load transient response, low noise and high power density which is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The SGI600-25 combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI600-25 ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI600-25.Features of the Sorensen SGI600-25 include:

  • High Power Density: 15kW in a 3U chassis
  • Wide Voltage Range: 0-600V and 0-25 Amps
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • Sequencing: Program custom waveforms
  • Easy-to-read Fluorescent Display: Supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only 
  • Specifications of the Sorensen SGI600-25 include:Common:

  • Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
  • Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
  • Series Operation: Up to 2 units (see Output Float Voltage)
  • Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 – 242 VAC); 380/400 VAC (operating range 342 – 440 VAC); and 440/480 VAC (operating range 396 – 528 VAC)
  • Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
  • Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and  >0.69 typical at 440/480 VAC input
  • Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
  • Environmental:

  • Operating Temperature: 0 to 50º C
  • Storage Temperature: -25º C to 65º C
  • Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
  • Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
  • Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
  • Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
  • Front Panel Dust Filter: 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature. 3U unit only.
  • Physical:

  • Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
  • Weight: 3U < 80 lbs. (36 kg) 6U
  • Output:

  • Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
  • Ripple (Cur Mode): <+/- 0.04% of full scale rms cur
  • DC Voltage Slew Rate: 45A / ms typical – resistive load
  • Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale
  • Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale
  • Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
  • Efficiency: 87% typical at nominal line and max load
  • Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
  • Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point
  • Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur.
  • Programming Specifications of the Sorensen SGI600-25 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
  • Cur Accuracy: 0.8% of full scale
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • OVP:

  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Read-Back / Monitoring Specifications of the Sorensen SGI600-25 include:Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Remote Analog Interface:

  • Accuracy: +/-1.0% of full scale (0 – 10V)
  • Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Cur Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •     

    Sorensen SGI600-25 Product Overview