Associated Research OMNIA II 8254 ELECTRICAL SAFETY COMPLIANCE Analyser The Associated Research OMNIA II 8254 Electrical Safety Compliance Analyser provides AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond / Continuity tests in a single DUT connection. An optional built-in 8 port scanner is available on the OMNIA II 8254. Designed around the way you test, the OMNI II 8254 is unique as your application and provides you with customizable features and unmatched functionality.Features and Specifications of the Associated Research OMNIA II 8254 Electrical Safety Compliance Analyser include:Features:
Comes standard with an USB/RS-232 interface
Available with optional Ethernet or GPIB
Color TFT display that makes setting up test files, viewing results and performing tests easier than ever
Customizable My Menu Interface
DualCHEK® simultaneous ground bond and hipot tests
Interconnection to scanning matrix
Storage of up to 10,000 test steps
Patented SmartGFI® function
Patented prompt and hold function
Patented CAL-ALERT® function
Patented VERI-CHECK® function
CHARGE LO® & RAMP HI®
40-Amp ground bond
Dual function ground bond and ground continuity
Built-in real cur measurement
4-Wire measurement
AC/DC Hipot leakage cur offset
Meets 200 mA short circuit requirements
True RMS cur readings
Specifications:
Input:
- Voltage: 115 / 230V auto-range, ± 15% variation
- Frequency: 50/60 Hz ± 5%
- Fuse: 115 VAC, 230VAC – 10A Slow-Blo 250VAC
Test functionality:
- 5 kV 100 mAAC Hipot (500VA)
- 5 kV 20 mADC Hipot
- Insulation Resistance
- 40 Amp Ground Bond
General Specifications:
- PLC Remote Control:
- Input: Test, Reset, Interlock, Recall File 1 through 3
- Output: Pass, Fail, Test-in-Process
- Safety: Built-in Smart GFI circuit
- Memory: 10,000 steps
- Interface: Standard USB/RS-232, Ethernet, or GPIB
- Security: Advanced security system with access levels and username/password requirements
- Alarm Volume Setting:
- Range: 0-9
- 0 = OFF
- 1 is softest volume and 9 is loudest volume
- Calibration:
- Adjustments are made through the front panel
- Automatic calibration alert function to signal operator when calibration is due
- Mechanical: Bench or rack mount with tilt up front teeth
Voltage: 115 / 230V auto-range, ± 15% variation
Frequency: 50/60 Hz ± 5%
Fuse: 115 VAC, 230VAC – 10A Slow-Blo 250VAC
5 kV 100 mAAC Hipot (500VA)
5 kV 20 mADC Hipot
Insulation Resistance
40 Amp Ground Bond
PLC Remote Control:
- Input: Test, Reset, Interlock, Recall File 1 through 3
- Output: Pass, Fail, Test-in-Process
Safety: Built-in Smart GFI circuit
Memory: 10,000 steps
Interface: Standard USB/RS-232, Ethernet, or GPIB
Security: Advanced security system with access levels and username/password requirements
Alarm Volume Setting:
- Range: 0-9
- 0 = OFF
- 1 is softest volume and 9 is loudest volume
Calibration:
- Adjustments are made through the front panel
- Automatic calibration alert function to signal operator when calibration is due
Mechanical: Bench or rack mount with tilt up front teeth
Input: Test, Reset, Interlock, Recall File 1 through 3
Output: Pass, Fail, Test-in-Process
Range: 0-9
- 0 = OFF
- 1 is softest volume and 9 is loudest volume
0 = OFF
1 is softest volume and 9 is loudest volume
Adjustments are made through the front panel
Automatic calibration alert function to signal operator when calibration is due