Keysight (Agilent) 34460A

Digital Multimeter, 6.5 digit

Manufacturer:
Model: Keysight (Agilent) 34460A
Description: Digital Multimeter, 6.5 digit
Data Sheet PDF: Keysight (Agilent) 34460A

Keysight 34460A (Agilent) The Keysight 34460A (Agilent) Digital Multimeter (DMM) is part of Agilent’sTruevolt Series – Keysight’s next generation of bench/system DMMs. The Keysight Truevolt 34460A DMM (Agilent) allows you to measure with unquestioned confidence, concentrate on the quality of your design not the quality of your measurement, and to easily control, capture, and view your data with a single click.Features and Specifications of the Keysight 34460A(Agilent) DMM  include:

  • Features:
    • Patented analog-to-digital converter enables a patented metrology-grade architecture
    • Uses patented digital direct sampling techniques to make AC rms measurements:
      • Results in a true rms calculation technique that avoids the slower response of the typical analog RMS converters
      • Allows for crest factors up to 10 without additional error terms
    • Minimized measurement error:
      • Contributes less than 30% of the injected cur
      • Offers almost 100% less noise compared to alternative DMMs
    • 11 measurement functions: DC/AC voltage, DC/AC cur, 2- and 4-wire resistance, diode, continuity, frequency, period, and temperature
    • Bright, 4.3 inch (109 mm), high-resolution, color, graphical display
    • Built-in bar chart, histogram, math and statistics:
      • Number mode provides traditional “digits” view of measurements
      • Bar meter mode provides number display along with an analog meter to provide a visual view of measurements
      • Histogram mode provides a statistical view of measurements
    • Customize display operation:
      • Configure your preferences
      • Pull them up automatically at the next instrument start-up
      • Add customized labels to describe the instrument’s measurement your way
    • DMM Connectivity Utility Software enables control, capture, and views of your DMM’s data on your PC or mobile device
    • All specifications tested, compliant and guaranteed according to ISO/IEC 17025
  • Specifications:
    • Resolution:  6½ digits
    • Input terminals:  Front
    • 1-year DCV accuracy ± (% of reading + % of range):  0.0075 + 0.0005
    • Measurement speed – 4½ digits:  300 readings/s
    • Measurements:
      • DCV, ACV, resistance, frequency, period, continuity: Same as 34401A baseline
      • Diode:  5 V
      • Cur:  100 µA – 3 A
      • Temperature:  RTD/PT100, thermistor
    • Iinternal memory:  1,000 readings
    • Graphical display:  Number, histogram, bar meter
    • I/O connectivity:  USB (LAN, GPIB optional)
  • Patented analog-to-digital converter enables a patented metrology-grade architecture
  • Uses patented digital direct sampling techniques to make AC rms measurements:
    • Results in a true rms calculation technique that avoids the slower response of the typical analog RMS converters
    • Allows for crest factors up to 10 without additional error terms
  • Minimized measurement error:
    • Contributes less than 30% of the injected cur
    • Offers almost 100% less noise compared to alternative DMMs
  • 11 measurement functions: DC/AC voltage, DC/AC cur, 2- and 4-wire resistance, diode, continuity, frequency, period, and temperature
  • Bright, 4.3 inch (109 mm), high-resolution, color, graphical display
  • Built-in bar chart, histogram, math and statistics:
    • Number mode provides traditional “digits” view of measurements
    • Bar meter mode provides number display along with an analog meter to provide a visual view of measurements
    • Histogram mode provides a statistical view of measurements
  • Customize display operation:
    • Configure your preferences
    • Pull them up automatically at the next instrument start-up
    • Add customized labels to describe the instrument’s measurement your way
  • DMM Connectivity Utility Software enables control, capture, and views of your DMM’s data on your PC or mobile device
  • All specifications tested, compliant and guaranteed according to ISO/IEC 17025
  • Results in a true rms calculation technique that avoids the slower response of the typical analog RMS converters
  • Allows for crest factors up to 10 without additional error terms
  • Contributes less than 30% of the injected cur
  • Offers almost 100% less noise compared to alternative DMMs
  • Number mode provides traditional “digits” view of measurements
  • Bar meter mode provides number display along with an analog meter to provide a visual view of measurements
  • Histogram mode provides a statistical view of measurements
  • Configure your preferences
  • Pull them up automatically at the next instrument start-up
  • Add customized labels to describe the instrument’s measurement your way
  • Resolution:  6½ digits
  • Input terminals:  Front
  • 1-year DCV accuracy ± (% of reading + % of range):  0.0075 + 0.0005
  • Measurement speed – 4½ digits:  300 readings/s
  • Measurements:
    • DCV, ACV, resistance, frequency, period, continuity: Same as 34401A baseline
    • Diode:  5 V
    • Cur:  100 µA – 3 A
    • Temperature:  RTD/PT100, thermistor
  • Iinternal memory:  1,000 readings
  • Graphical display:  Number, histogram, bar meter
  • I/O connectivity:  USB (LAN, GPIB optional)
  • DCV, ACV, resistance, frequency, period, continuity: Same as 34401A baseline
  • Diode:  5 V
  • Cur:  100 µA – 3 A
  • Temperature:  RTD/PT100, thermistor
  •     

    Keysight Agilent

    Keysight (Agilent) 34460A Product Overview